Specifications
| Model | 200W | 1kW | 5kW | 10kW | |
|---|---|---|---|---|---|
| Windmill | Structure | monopole | 4-poles | ||
| Blade Length | 1.6m (5.25ft) | 3.5m (11.48ft) | 5m (16.4ft) | 4.5m (14.76ft) | |
| Blade Rotation Diameter | 1.3m (4.26ft) | 2.1m (6.89ft) | 4.5m (14.76ft) | 5m (16.4ft) | |
| Number of Blades | 4 | 8 | |||
| Blade Width | 300mm (1ft) | 1300mm (4.2ft) | |||
| Blade Material | Anti-Rusting Aluminum | ||||
| Weight | 20kg (44lb) | 60kg (132lb) | 620kg (1364lb) | 1500kg (3300lb) | |
| Total Height with Pole | 7m (22.96ft) | 7.5m (24.6ft) | 13m (62.64ft) | ||
| Generator | Specifications | PMSG | |||
| Rated Output (at 12 m/s wind velocity) |
200W | 1KW | 5KW | 10KW | |
| System Function | Minimum Rotating Wind Velocity | 1.4m/sec (3.1mph) | 1.6m/sec (3.6mph) | 1.8m/sec (4mph) | 2.0m/sec (4.5mph) |
| Kick-in Wind Velocity | 2.8m/sec (6.3mph) | ||||
| Survival Wind Velocity | 60m/sec (134.4mph) | 40m/sec (89.6mph) | |||
| Voltage | DC output | AC200V | |||
| Battery (Owner supplied, reference only) |
12V35Ah x 3 | 12V60Ah x 10 | - | ||
| Grid Connection | No | Yes in USA | |||
| System | Independent | Independent | |||
| Grid | |||||
| Solar Panel | 70W x 2 | Option | |||
| Co-Operation with Utility * | Option | ||||
| Typical Application | LED night light | Cell Tower | Building Roof | Self-supplied for farmers |
|
| Model | 200W | 1kW | |
|---|---|---|---|
| Windmill | Structure | monopole | |
| Blade Length | 1.6m(5.25ft) | 3.5m(11.48ft) | |
| Blade Rotation Diameter | 1.3m(4.26ft) | 2.1m(6.89ft) | |
| Number of Blades | 4 | ||
| Blade Width | 300mm(1ft) | ||
| Blade Material | Anti-Rusting Aluminum | ||
| Weight | 20kg(44lb) | 60kg(132lb) | |
| Total Height with Pole | 7m(22.96ft) | ||
| Generator | Specifications | PMSG | |
| Rated Output (at 12 m/s wind velocity) | 200W | 1KW | |
| System Function | Minimum Rotating Wind Velocity | 1.4m/sec (3.1mph) |
1.6m/sec (3.6mph) |
| Kick-in Wind Velocity | 2.8m/sec(6.3mph) | ||
| Survival Wind Velocity | 60m/sec(134.4mph) | ||
| Voltage | DC output | ||
| Battery (Owner supplied, reference only) | 12V35Ah x 3 | 12V60Ah x 10 | |
| Grid Connection | No | ||
| System | Independent | ||
| Solar Panel | 70W x 2 | Option | |
| Co-Operation with Utility * | Option | ||
| Typical Application | LED night light | Cell Tower | |
| Model | 5kW | 10kW | |
|---|---|---|---|
| Windmill | structure | monopole | 4-poles |
| Blade Length | 5m(16.4ft) | 4.5m(14.76ft) | |
| Blade Rotation Diameter | 4.5m(14.76ft) | 5m(16.4ft) | |
| Number of Blades | 4 | 8 | |
| Blade Width | 1300mm(4.2ft) | ||
| Blade Material | Anti-Rusting Aluminum | ||
| Weight | 620kg(1364lb) | 1500kg(3300lb) | |
| Total Height with Pole | 7.5m(24.6ft) | 13m(62.64ft) | |
| Generator | Specifications | PMSG | |
| Rated Output (at 12 m/s wind velocity) | 5KW | 10KW | |
| System Function | Minimum Rotating Wind Velocity | 1.8m/sec (4mph) |
2.0m/sec (4.5mph) |
| Kick-in Wind Velocity | 2.8m/sec(6.3mph) | ||
| Survival Wind Velocity | 60m/sec (134.4mph) |
40m/sec (89.6mph) |
|
| Voltage | AC200V | ||
| Battery | - | ||
| Grid Connection | Yes in USA | ||
| System | Independent | ||
| Grid | |||
| Solar Panel | Option | ||
| Co-Operation with Utility * | Option | ||
| Typical Application | Building Roof | Self-supplied for farmers | |
The specification is subject to change without notice.
* This is the device to switch to utility power when the wind turbine output is not enough.
Approximate power generation
(Unit : W)
| Wind Velocity | 200W | 1kW | 5kW | 10kW |
|---|---|---|---|---|
| 0 〜 2 m/sec | 0 | 0 | 0 | 0 |
| 2 〜 3 m/sec | 6 | 30 | 130 | 300 |
| 3 〜 4 m/sec | 10 | 50 | 270 | 500 |
| 4 〜 5 m/sec | 18 | 90 | 520 | 900 |
| 5 〜 6 m/sec | 24 | 120 | 870 | 1200 |
| 6 〜 7 m/sec | 38 | 190 | 1330 | 1900 |
| 7 〜 8 m/sec | 56 | 280 | 1880 | 2800 |
| 8 〜 9 m/sec | 80 | 400 | 2530 | 4000 |
| 9 〜 10 m/sec | 110 | 550 | 3280 | 5500 |
| 10 〜 11 m/sec | 160 | 800 | 4140 | 8000 |
| 11 〜 12 m/sec | 196 | 980 | 4851 | 9800 |
| 12 m/sec more | 200 | 1000 | 5000 | 10000 |
Wind conditions vary depending on location and terrain. This chart is only a guideline and does not guarantee power generation.